Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.442
Filtrar
1.
Int J Clin Pediatr Dent ; 17(1): 41-47, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38559868

RESUMO

Background and aim: To establish lesion sterilization and tissue repair (LSTR) therapy as an alternate treatment option in managing infected primary molars with poor prognosis that were indicated for extraction, thereby fulfilling the objective of retaining the primary tooth till its normal exfoliation in the dental arch. Materials and methods: A total of 84 children who met the inclusion criteria requiring extraction in 142 teeth involving primary molars were included in the study. The selected patients were allocated to two groups, that is, group I-LSTR therapy with 3Mix-MP paste and group II-pulpectomy with metapex. All the treated teeth were then clinically and radiographically evaluated after 1, 3, 6, 9, and 12 months, respectively, to determine the success between groups I and II. Pearson's Chi-squared test along with the z-test was used to compare the clinical and radiographic success of the two groups (p < 0.05). Results: Pain and tenderness were completely resolved within one month of follow-up in both groups. Abscesses were resolved completely at 1 month in the pulpectomy group and mobility was resolved at 6 months follow-up in both groups. Interradicular and periradicular radiolucency persisted even at 12 months of the follow-up period in both groups. The intergroup comparison revealed no statistical differences between LSTR and pulpectomy procedure and both were equally effective at all time intervals (p > 0.05). Conclusion: Both LSTR therapy with 3Mix-MP and pulpectomy with metapex showed 100% clinical success rates. Radiographically no changes were observed even at the 12-month follow-up period in both groups. LSTR therapy can be an alternative treatment option for pulpally involved primary teeth with poor prognosis and in cases where mechanical instrumentation could not be achieved due to physiologic root resorption. How to cite this article: Sefa I, Garg N, Pathivada L, et al. Success of Lesion Sterilization and Tissue Repair Therapy and Pulpectomy in the Management of Infected Primary Molars with Poor Prognosis. Int J Clin Pediatr Dent 2024;17(1):41-47.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S717-S719, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595356

RESUMO

Objectives: The objectives of the current study was to evaluate the disinfection efficacy of ozone, ultraviolet (UV) radiation, herbal and glutaraldehyde method for sterilization of elastomeric impression materials. Materials and Methods: Disinfection of elastomeric impression material was performed with each of the disinfection methods: ozone, UV radiation, herbal, and glutaraldehyde. Later microbiological analysis was performed and the colony-forming units were evaluated and compared. Results: The highest disinfection efficacy was found with glutaraldehyde, followed by ozone and UV radiation, and the least with neem herbal rinse. Intergroup comparison was highly significant. Conclusion: Dry gaseous ozone and UV radiation can be used effectively for the disinfection of impressions.

3.
J Pharm Bioallied Sci ; 16(Suppl 1): S75-S77, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595433

RESUMO

As part of lesion sterilization and tissue restoration (LSTR), treatment for primary molars affected by extensive periapical pathosis and extreme resorption entails the use of a triple antibiotic mixture in an appropriate medium. In-depth explanation of all components of LSTR is the main focus of this review of the literature.

4.
J Pharm Bioallied Sci ; 16(Suppl 1): S152-S155, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595471

RESUMO

Objective: The purpose of this study was to determine the effect of common methods of sterilization on the tensile strength of Beta titanium, Stainless steel, Australian Stainless steel, Copper Nickel-Titanium, and Nickel-Titanium wires. It also aimed to evaluate the changes in tensile strength values caused by repeated cycles of sterilization. Materials and Methods: A sample of 225 orthodontic wires, i.e., beta-titanium, stainless steel, Australian stainless steel, copper nickel-titanium, and nickel-titanium wires, were collected from different manufacturers. These wires were divided into three groups, which consists of Groups 1, 2, and 3. Four methods of sterilization used in this study were as follows: (i) autoclave (250°F for 20 min), (ii) dry heat sterilization (375°F for 20 min), (iii) ethylene oxide sterilization (54°C for 4 hrs), and (iv) 2.45% acidic glutaraldehyde (10 hrs). Results: The results of this study showed that there was increase in tensile strength of beta-titanium and nickel-titanium wires using autoclave and dry heat sterilization. No statistically significant difference in tensile strength of stainless steel and Australian stainless steel archwires. The tensile strength of copper nickel-titanium wires decreased following 0, 1, and 5 cycles of sterilization. Conclusion: The lack of statistically significant differences established in the study of new and sterilized orthodontic archwires gives us reason to conclude that the orthodontic arch wires can be sterilized because the sterilizing processes do not affect their tensile strength and the orthodontists could thus ensure the maximum safety of their patients.

5.
Integr Comp Biol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587825

RESUMO

The "adaptive sterilization hypothesis" argues that the tendency of sexually transmitted infections (STIs) to cause infertility likely reflects an evolutionary adaptation of these pathogens. For example, some STIs can lead to bilateral occlusions of the oviducts and sterile matings. Cycling females that do not spend time gestating and lactating are ready to mate sooner than fertile females, and therefore, likely to mate more frequently and possibly more promiscuously. These sexual activities are associated with enhanced transmissibility of STIs, and tubal occlusion is a proximate mechanism by which STIs can increase fitness. Our principal objectives were to determine whether female mice inoculated with Chlamydia muridarum mate more frequently than mice inoculated with sterile saline and to test the hypothesis that tubal occlusion following C. muridarum infection modulates mating behavior in a manner that might increase transmissibility of Chlamydia. Similar to C. trachomatis infections in human females, C. muridarum can ascend the reproductive tract of mice, damage and occlude the oviducts, and cause infertility. However, ovarian function and mating activity are maintained following tubal occlusion. Twenty C57Bl/6 mice with regular estrous cycles were given intra-vaginal inocula of C. muridarum and 32 days later paired with a male for 90 days. Nine saline-treated females served as controls. Three Chlamydia-inoculated females were rendered infertile due to bilateral oviductal damage and mated 8 (±0.0) times. Control females mated on average 4.6 (±0.3) times, and 17 Chlamydia-inoculated fertile females, including six females with only a single oviduct occluded, mated on average 4.7 (±0.2) times. Chlamydia-inoculated fertile females with unilateral oviductal damage had significantly smaller average litter sizes as compared to females inoculated with saline. Females with unilateral tubal occlusion also tended to wean fewer pups than saline controls over the course of 90 days. Female mice with Chlamydia-induced tubal infertility mated more frequently (approximately every 11 d) than did fertile females (approximately every 20 d), which is consistent with the adaptive sterilization hypothesis. To determine whether Chlamydia-induced sterilization is truly adaptive, future studies will need to demonstrate increased sexual transmissibility, and possibly increased promiscuity, within populations of freely breeding mice.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38629436

RESUMO

Plasmonic nanozymes bring enticing prospects for catalytic sterilization by leveraging plasmon-engendered hot electrons. However, the interface between plasmons and nanozymes as the mandatory path of hot electrons receives little attention, and the mechanisms of plasmonic nanozymes still remain to be elucidated. Herein, a plasmonic carbon-dot nanozyme (FeCG) is developed by electrostatically assembling catalytic iron-doped carbon dots (Fe-CDs) with plasmonic gold nanorods. The energy harvesting and hot-electron migration are remarkably expedited by a spontaneous organic-inorganic heterointerface holding a Fermi level-induced interfacial electric field. The accumulated hot electrons are then fully utilized by conductive Fe-CDs to boost enzymatic catalysis toward overproduced reactive oxygen species. By synergizing with localized heating from hot-electron decay, FeCG achieves rapid and potent disinfection with an antibacterial efficiency of 99.6% on Escherichia coli within 5 min and is also effective (94.2%) against Staphylococcus aureus. Our work presents crucial insights into the organic-inorganic heterointerface in advanced plasmonic biocidal nanozymes.

7.
Biochem Biophys Res Commun ; 710: 149890, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38608491

RESUMO

Low level expression in Escherichia coli of the RecA protein from the radiation resistant bacterium Deinococcus radiodurans protects a RecA deficient strain of E. coli from UV-A irradiation by up to ∼160% over basal UV-A resistance. The protection effect is inverse protein dose dependent: increasing the expression level of the D. radiodurans RecA (DrRecA) protein decreases the protection factor. This inverse protein dose dependence effect helps resolve previously conflicting reports of whether DrRecA expression is protective or toxic for E. coli. In contrast to the D. radiodurans protein effect, conspecific plasmid expression of E. coli RecA protein in RecA deficient E. coli is consistently protective over several protein expression levels, as well as consistently more protective to higher levels of UV-A exposure than that provided by the D. radiodurans protein. The results indicate that plasmid expression of D. radiodurans RecA can modestly enhance the UV resistance of living E. coli, but that the heterospecific protein shifts from protective to toxic as expression is increased.


Assuntos
Deinococcus , Escherichia coli , Escherichia coli/genética , Escherichia coli/metabolismo , Deinococcus/genética , Deinococcus/metabolismo , Recombinases Rec A/genética , Recombinases Rec A/metabolismo , Plasmídeos/genética , Raios Ultravioleta , Reparo do DNA , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo
8.
J Biosci Bioeng ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38570220

RESUMO

The choice of sterilization method for hydrogels used for cell culture influences the ease of preparing the gel. We prepared interpenetrating gelatin/calcium alginate hydrogels containing 1% (w/v) alginate and 1-16% (w/v) gelatin by molding with the mixture of gelatin/sodium alginate solution, followed by the addition of calcium ions by incubation in calcium chloride solution. It is the simplest method to prepare autoclavable gelatin/sodium hydrogel. We measured various properties of the hydrogels including volume, Young's modulus in the compression test, storage modulus, and loss modulus in the dynamic viscoelasticity measurement. The gelatin/alginate hydrogel can be easily fabricated into any shape by this method. After autoclave treatment, the hydrogel was shrunk to smaller than the original shape in similar figures. The shape of the gelatin/alginate hydrogel can be designed into any shape with the reduction ratio of the volume. Human osteosarcoma (HOS) cells adhered to the gelatin/alginate hydrogel and then proliferated. Gelatin/calcium alginate hydrogels with a high concentration are considered to be autoclavable culture substrates because of their low deformation and gelatin elution rate after autoclaving and the high amount of cells attached to the hydrogels.

9.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580975

RESUMO

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Assuntos
Desinfecção , Controle de Infecções , Humanos , Estudos Transversais , China , Instrumentos Odontológicos
10.
Sci Total Environ ; 928: 172353, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38614351

RESUMO

This study addresses the energy-intensive nature of conventional wastewater treatment processes and proposes a solution through the development of a green, low-energy, and multifunctional wastewater treatment technology. The research focuses on a multifunctional self-driven photoelectrocatalytic (PEC) system, exploring its four-in-one applications in eliminating organic pollutants, reducing U(VI), generating electrical energy, and disinfecting pathogenic microorganisms. A TiO2-decorated carbon felt (CF@TiO2) cathode is synthesized to enhance interfacial charge transfer, with TiO2 coating improving surface binding sites (edge TiO and adsorbed -OH) for UO22+ adsorption and reduction. The self-driven PEC system, illuminated solely with simulated sunlight, exhibits remarkable efficiency in removing nearly 100 % of uranium within 0.5 h and simultaneously degrading 99.9 % of sulfamethoxazole (SMX) within 1.5 h, all while generating a maximum power output density (Pmax) of approximately 1065 µW·cm-2. The system demonstrates significant anti-interference properties across a wide pH range and coexisting ions. Moreover, 49.4 % of the fixed uranium on the cathode is reduced into U(IV) species, limiting its migration. The self-driven PEC system also excels in detoxifying various toxic organic compounds, including tetracycline, chlortetracycline, and oxytetracycline, and exhibits exceptional sterilization ability by disinfecting nearly 100 % of Escherichia coli within 0.5 h. This work presents an energy-saving, sustainable, and easily recyclable wastewater purification system with four-in-one capabilities, relying solely on sunlight for operation.

11.
Ann Pharm Fr ; 2024 Apr 17.
Artigo em Francês | MEDLINE | ID: mdl-38641001

RESUMO

OBJECTIVES: In order to share their knowledge, sterilization unit managers publish the results of their work in journals or at scientific conferences. The aim of Enthalpies is to list all such work in a single database. The work presented describes the construction of this database and the assessment of its feasibility for the washing step. METHODS: The first step was to carry out a literature review. Only articles published over 10 years (2013-2023) in connection with the ten-year washing stage were included. Then, each publication was categorized, coded, graded and summarized by a pharmacist-internal pair. All this data was collated in an Excel® spreadsheet, and from the data categorization a tree structure was created, enabling the interface between the user and the platform hosting Enthalpies to be understood. RESULTS: 81 publications were identified. These were categorized into 6 themes and 27 sub-themes. A reading grid was drawn up for each publication. Genially®, an online platform, was chosen to host our database. CONCLUSION: Enthalpies was not designed to issue recommendations for best practice. However, by collating published scientific data, this tool can be used to assist decision-making. It represents an innovative solution for providing a literature review in the field of hospital sterilization.

12.
Cureus ; 16(3): e56516, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38646327

RESUMO

INTRODUCTION: Therapeutic plasma exchange (TPE) is used to manage various life-threatening illnesses. It is widely performed by nephrologists, intensivists, pathologists, or experts in transfusion medicine worldwide. However, the costs of TPE sessions are exceedingly high, and they have a huge impact on patients' financial burden. Herein, we investigated the outcomes of the reuse of plasma filters in TPE on several occasions. METHODS: This is a retrospective analysis of patients receiving TPE from January 1, 2020, to April 30, 2023, in the Department of Nephrology. A formulation of 4.5% peracetic acid and 24% hydrogen peroxide acid with RO water dilution was used for reprocessing. Clinical outcomes, risks, and cost-benefit were evaluated and compared between the plasma filter reuse group (GP-1) and the no-reuse group (GP-2). RESULTS: A total of 70 patients were included in this study. 200 and 112 TPE sessions were performed in GP-1 and GP-2, respectively. The most common indication for TPE in both groups was neurological. The clinical efficacy of TPE was similar in both groups. There was no difference in the clotting of the plasma filter, any allergic reaction, infection, or bleeding in the group. However, there was a significant difference in levels of fibrinogen (p=0.03) pre and post-procedure in both groups. The incidence of hypotension was found to be higher in GP-1 (26%) compared to GP-2 (15.6%), p = 0.05. The cost of overall treatment was 38% less in GP-1. CONCLUSION: The reuse of plasma filters is a safe and effective method for cost minimization in patients requiring TPE. This method can be effectively utilized in resource-poor settings without any increased risk of adverse effects.

13.
Food Chem ; 450: 139359, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38631204

RESUMO

The effects of different thermal sterilization conditions on the quality and digestibility of ready-to-eat (RTE) shrimp were investigated. Compared with the high-temperature (121 °C) and short-time (6 min and 8 min) sterilization, the low-temperature (110 and 115 °C) and long-time (>20 min) sterilization significantly promoted the Maillard and browning reactions and changed the color of the RTE-shrimp. The high sterilization temperature promoted shrimp protein oxidation, resulting in increased carbonyl group, disulfide bond, and free radical content, while the free sulfhydryl group content decreased. This oxidation and tissue destruction at high temperature led to reduced texture properties and altered water distribution within the shrimp's muscles. However, sterilized shrimp exhibited superior digestive properties in an in vitro simulated digestion experiment. High-temperature and short-time sterilization is more effective in mitigating the quality deterioration of RTE-shrimp compared to low-temperature and long-time sterilization.

14.
Front Bioeng Biotechnol ; 12: 1275709, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633664

RESUMO

Large bone defect regeneration remains a major challenge for orthopedic surgeons. Tissue engineering approaches are therefore emerging in order to overcome this limitation. However, these processes can alter some of essential native tissue properties such as intermolecular crosslinks of collagen triple helices, which are known for their essential role in tissue structure and function. We assessed the persistence of extracellular matrix (ECM) properties in human fascia lata (HFL) and periosteum (HP) after tissue engineering processes such as decellularization and sterilization. Harvested from cadaveric donors (N = 3), samples from each HFL and HP were decellularized following five different chemical protocols with and without detergents (D1-D4 and D5, respectively). D1 to D4 consisted of different combinations of Triton, Sodium dodecyl sulfate and Deoxyribonuclease, while D5 is routinely used in the institutional tissue bank. Decellularized HFL tissues were further gamma-irradiated (minimum 25 kGy) in order to study the impact of sterilization on the ECM. Polarized light microscopy (PLM) was used to estimate the thickness and density of collagen fibers. Tissue hydration and content of hydroxyproline, enzymatic crosslinks, and non-enzymatic crosslinks (pentosidine) were semi-quantified with Raman spectroscopy. ELISA was also used to analyze the maintenance of the decorin (DCN), an important small leucine rich proteoglycan for fibrillogenesis. Among the decellularization protocols, detergent-free treatments tended to further disorganize HFL samples, as more thin fibers (+53.7%) and less thick ones (-32.6%) were recorded, as well as less collagen enzymatic crosslinks (-25.2%, p = 0.19) and a significant decrease of DCN (p = 0.036). GAG content was significantly reduced in both tissue types after all decellularization protocols. On the other hand, HP samples were more sensitive to the D1 detergent-based treatments, with more disrupted collagen organization and greater, though not significant loss of enzymatic crosslinks (-37.4%, p = 0.137). Irradiation of D5 HFL samples, led to a further and significant loss in the content of enzymatic crosslinks (-29.4%, p = 0.037) than what was observed with the decellularization process. Overall, the results suggest that the decellularization processes did not significantly alter the matrix. However, the addition of a gamma-irradiation is deleterious to the collagen structural integrity of the tissue.

15.
3D Print Med ; 10(1): 14, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656429

RESUMO

BACKGROUND: Surgical guides can improve the precision of implant placement and minimize procedural errors and their related complications. This study aims to determine how different disinfection and sterilization methods affect the size changes of drill guide templates and the mechanical properties of 3D-printed surgical guides made with LCD technology. METHODS: We produced a total of 100 samples. Forty surgical guides were fabricated to assess the implant drill guides' surface and geometric properties. We subjected sixty samples to mechanical tests to analyze their tensile, flexural, and compressive properties. We classified the samples into four groups based on each analytical method: GC, which served as the control group; GA, which underwent autoclave sterilization at 121 °C (+ 1 bar, 20 min); GB, which underwent autoclave sterilization at 134 °C (+ 2 bar, 10 min); and GL, which underwent disinfection with 70% isopropyl alcohol for 20 min. RESULT: The results show that sterilization at 121 °C and 134 °C affects the mechanical and geometric characteristics of the surgical guides, while disinfection with 70% isopropyl alcohol gives better results. CONCLUSION: Our study of 3D-printed surgical guides using LCD technology found that sterilization at high temperatures affects the guides' mechanical and geometric properties. Instead, disinfection with 70% isopropyl alcohol is recommended.

16.
Ann Pharm Fr ; 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38649136

RESUMO

OBJECTIVES: The standard process of central sterilization is crucial for the optimal functioning of the operating room. The outcome of this process is closely linked to the steps preceding the steps prior to the sterilization step itself. These steps include pre-disinfection carried out in the operating rooms and other stages, namely washing, drying and packaging, which must be performed in the central sterilization unit. In this context, this study aimed to describe the knowledge of the staff in the operating rooms and the central sterilization unit at Sahloul University Hospital in Sousse (Tunisia) in 2022, regarding the steps prior to the sterilization of reusable thermoresistant medical devices and to describe their practices in terms of compliance with these steps. METHOD: A descriptive study was conducted from January 2022 to June 2022 with the aforementioned staff, using a self-administered questionnaire to assess their knowledge of the pre-sterilization steps and a direct observation audit of their practices with regard to these steps. Both measurement instruments were pre-tested. RESULTS: Out of 102 self-administered questionnaires (knowledge assessment) distributed to the staff concerned, only 80 were returned and correctly filled out, giving a response rate of 78.4%. Participants' responses regarding the order of steps prior to the sterilization were incorrect in 64% of cases. With regard to the evaluation of professional practices, 224 observations were made in the study area (practice audit). In 82% of these observations, the pre-disinfection step was confused with the washing step. The use of Betadine brushes and scrubbing pads for device washing was noted in 89.3%, along with the absence of swabbing of the canals and hollow parts in 9.4% of cases and the absence of drying of the canals with compressed air. CONCLUSION: Mastery of the steps prior to sterilisation of reusable thermoresistant medical devices was insufficient in our institution, suggesting the importance of reinforcing the implementation of the procedure through a continuous training program followed by action plans.

17.
J Health Psychol ; : 13591053241240922, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654481

RESUMO

Understanding socio-cultural factors that influence older (age 50 and up) Black women's risk for sexually transmitted HIV has often been absent from policies and programs. This scoping review asked: What does academic literature reveal about forced/coerced sterilization as a risk factor for older Black women who are disproportionately affected by sexually transmitted HIV? Using the Arksey and O'Malley scoping review methodology, the authors identified academic and gray literature published between 2000 and 2023. Of the 407 sources identified and screened, three articles met the criteria for inclusion. One study focused on birth control conspiracy beliefs, another focused on racial differences in Norplant use, and the third focused on the intergenerational transmission of mistrust of medical care that influences HIV prevention among Black Americans. The study findings suggest that because the link has not been made between socio-cultural factors that impact older Black women's reproductive health practices, further investigation is warranted.

18.
Heliyon ; 10(6): e27927, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38515695

RESUMO

This study has investigated the effect of ultrasound (US) as an emerging non-thermal sterilization technique on microbial growth and quality changes in three freshly squeezed pumpkin juices (Cucurbita maxima Duchesne, Cucurbita moschata Duchesne, and Cucurbita pepo L.).The three pumpkin juices were ultrasonicated at different ultrasonic power (0-400 W), time (0-20 min), and temperature (0-30 °C), and the total colony counts of the treated pumpkin juices were less than 5 log CFU/mL, which complied with the food safety and consumption standards. Based on these results, we further investigated the effects of different ultrasonic power (25 kHz, 10 min, 20 °C, 0-400 W) on the physicochemical properties and sensory quality of the three pumpkin juices. The physicochemical properties (color, sugar content, organic acid content, soluble solids, and carotenoids) of treated pumpkin juice were retained or improved to some extent. The antioxidant capacity was also increased by 9.09%, 10.25%, and 16.9% compared to the untreated group. During sonication, the particle size of all samples decreased significantly, the microstructure broke down significantly, and the sensory qualities of pumpkin juice were well preserved after sonication.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38502830

RESUMO

Background: Tubal sterilization is more commonly utilized by racial/ethnic minority groups and has been implicated in underscreening for cervical cancer. The objective is to determine if prior tubal sterilization is a risk factor for cervical cancer underscreening. Methods: National Survey of Family Growth dataset from 2015 to 2019 used for analysis; data were weighted to represent the 72 million women in the U.S. population aged 22-49. Chi-square tests, Fisher exact tests, and logistic regression were used for analysis. The primary predictor variable was tubal sterilization which was categorized into no previous sterilization, sterilization completed <5 years ago, and sterilization completed ≥5 years ago. The outcome variable was underscreened versus not underscreened. Other predictor variables included age, household income as a percent of federal poverty level, previous live birth, primary care provider, and insurance status. Results: Prevalence of tubal sterilization completed 5 or more years ago was 12.5% and varied by most measured characteristics in univariate analyses. Approximately 8% of women were underscreened for cervical cancer. In multivariable analyses, women with a tubal sterilization 5 or more years ago had 2.64 times the odds (95% confidence interval = 1.75-4.00) of being underscreened for cervical cancer compared with women who did not have a tubal sterilization. Conclusions: Approximately 4.3 million women ages 22-49 in the United States are potentially underscreened for cervical cancer and women with previous tubal ligation ≥5 years ago are more likely to be underscreened. These results may inform the need for culturally sensitive public health messages informing people who have had these procedures about the need for continued screening.

20.
Cureus ; 16(2): e54427, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38510902

RESUMO

Objectives This study aimed to assess the awareness, implementation, and compliance with the infection control policy recommended by the Saudi Ministry of Health (MOH) for the use and reprocessing of endodontic files and to examine the association between compliance and gender, experience, clinical ranks, and workplace sector. Methods This was a cross-sectional study conducted using a validated self-administered electronic questionnaire created and distributed to dentists who perform endodontic treatment in Saudi Arabia. Data were collected between June and July 2023. Descriptive statistics were reported as counts and percentages. Comparisons among the demographic groups were done using the Kruskal-Wallis and Mann-Whitney tests. Results A total of 402 dentists completed the survey. The results showed that 76.1% (n=306) of respondents claimed that they were aware of the infection control policy recommended by the Saudi MOH for the use and reprocessing of endodontic files in dental clinics. Only 13.2% (n=53) of dentists used single-use endodontic files, and 36.6% (n=147) did not use an endodontic box in their dental clinics. The most commonly reported method of tracing the number of uses of endodontic files was to write the ID of the patient or the number of uses on the sterilization pouch as reported by 37.6% of participants (n=151). The average compliance score percentage was 63.5 ± 16.7. Most of the respondents showed moderate to high levels of compliance (51.7% (n=208) and 42.0% (n=169) of dentists, respectively). Dentists with less than 5 years of experience showed significantly less compliance than dentists with more than 10 years of experience (p = 0.005). Gender, clinical rank, and workplace sector were not significantly associated with the extent of adhering to the evaluated infection control policy. Conclusions Our findings indicate a relatively high level of compliance with the Saudi MOH policy of using and reprocessing endodontic files. However, critical measures such as the single-use of endodontic files, sterilizing new endodontic files, and using the sterilized endodontic box for each patient need improvement. Hence, this study recommends enhancing awareness through continuous education and training.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...